[Environmental Equipment Delivery Case] Dust Removal Tower

Processing gas volume 70 Nm3/h x 2 series! The coarse removal rate before the filter is designed for an 80% removal efficiency!

We would like to introduce a case of dust removal tower delivered by E-Techno. The cleaning liquid is water, and the design removal rate for coarse particles before the filter is 80%. The substances to be removed include dust and acidic gases, with particle sizes ranging from 1μm to 40μm, of which more than 85% are over 10μm. 【Case Study】 ■ Industry of Delivery: Chemical ■ Designed and Installed Equipment: Dust Removal Tower EHCU Series ■ Process Gas Volume: 70Nm3/h x 2 systems ■ Substances to be Removed: Includes dust and acidic gases ■ Gas Temperature: Max. 80℃ ■ Particle Size: 1μm to 40μm (more than 85% are over 10μm) ■ Design Removal Rate: Coarse removal before the filter 80% ■ Cleaning Liquid: Water *For more details, please refer to the PDF document or feel free to contact us.

  • Gas equipment
  • others

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Case Study of Environmental Equipment] Methyl Acrylate Gas Removal Tower

Removal rate of 90% or more based on design values! Case study of removal target gases such as methyl acrylate and toluene.

Here is a case study of the delivery of a methyl acrylate gas removal tower conducted by E-Techno. The target gases and their concentrations are methyl acrylate at 200 ppm, toluene at 1600 ppm, cyclohexane at 100 ppm, and methanol at 20 ppm. The processing gas volume is 6000 m³/h, with a removal rate of over 90% based on design values. 【Case Study】 ■ Industry of delivery destination: Chemical ■ Designed and installed equipment: Methyl acrylate gas removal tower E730 series ■ Processing gas volume: 6000 m³/h ■ Gas temperature: 35℃ ■ Removal rate: Over 90% based on design values ■ Packing tower: ID 1200×H5015 (packing height 2m) SUS304 ■ Packing material: Hyrex 200PP *For more details, please refer to the PDF document or feel free to contact us.

  • Gas equipment
  • others

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Delivery Example] Ethylene Oxide and Propylene Oxide Removal Tower

Removal from 715,000 ppm to below 40 ppm! Reactively converted to EG and PG using dilute sulfuric acid aqueous solution.

We would like to introduce a case study of the ethylene oxide and propylene oxide removal tower supplied by E-Techno. The gas temperature is 60°C, and the convergence temperature due to reaction heat is 72.1°C. The reaction conversion to EG and PG is performed using a dilute sulfuric acid aqueous solution. The processing gas volume is 914.2 Nm³/h, and the design removal rate reduces the concentration from 715,000 ppm to below 40 ppm. 【Case Study】 ■ Industry of the recipient: Resin ■ Designed and installed equipment: Ethylene oxide and propylene oxide removal tower ■ Processing gas volume: 914.2 Nm³/h ■ Target substances for removal: EO, PO ■ Gas temperature: 60°C ■ Convergence temperature due to reaction heat: 72.1°C ■ Design removal rate: Reducing from 715,000 ppm to below 40 ppm *For more details, please refer to the PDF document or feel free to contact us.

  • Gas equipment
  • others

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Case Study of Environmental Equipment] Isopropyl Alcohol Removal Tower

Gas concentration is 9300 ppm! Case study of the delivery of an isopropyl alcohol removal tower with a designed removal rate of 80-90%.

We would like to introduce a case study of the isopropyl alcohol removal tower delivered by E-Techno. The target substance for removal is IPA, with a processing gas flow rate of 20m3/min, a supply water temperature of Max. 28℃, and a processing gas concentration of 9300ppm. The absorbent is water, and the designed removal rate is 80-90%. 【Case Study】 ■ Industry of Delivery: Chemical ■ Designed and Installed Equipment: Isopropyl Alcohol Removal Tower EHCU Series ■ Processing Gas Flow Rate: 20m3/min ■ Target Substance for Removal: IPA ■ Gas Temperature: Max. 35℃ ■ Supply Water Temperature: Max. 28℃ ■ Processing Gas Concentration: 9300ppm ■ Designed Removal Rate: 80-90% *For more details, please refer to the PDF document or feel free to contact us.

  • Gas equipment
  • others

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Environmental Equipment Delivery Case] High-Concentration Chlorine Gas and Cyanide Gas Removal Tower

The outlet concentration should be below 2ppm for cyanide gas! We will introduce examples of the delivery of high-concentration chlorine gas and cyanide gas removal towers.

We would like to introduce a case study of the high-concentration chlorine gas and cyanide gas removal tower delivered by E-Techno. The target gases for removal are chlorine gas and cyanide gas, with a maximum processing capacity of 3600 Nm³/h. The inlet concentrations are a maximum of 2 vol% for chlorine gas and 15 vol% for cyanide gas, while the outlet concentrations are 0.5 ppm for chlorine gas and below 2 ppm for cyanide gas. 【Case Study】 ■ Industry of Delivery: Chemical ■ Designed and Installed Equipment: High-Concentration Chlorine Gas and Cyanide Gas Removal Tower ■ Processing Capacity: Max. 3600 Nm³/h ■ Target Gases for Removal: Chlorine Gas, Cyanide Gas ■ Inlet Concentration: Max. 2 vol% for Chlorine Gas, 15 vol% for Cyanide Gas ■ Outlet Concentration: 0.5 ppm for Chlorine Gas, below 2 ppm for Cyanide Gas *For more details, please refer to the PDF document or feel free to contact us.

  • Gas equipment
  • others

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Case Study of Environmental Equipment Installation] Hydrochloric Acid Gas Removal Tower

The absorption by water is Max 90°C! Here we present a case where the outlet concentration of hydrochloric acid gas was below 5 ppm.

We would like to introduce a case where E-Techno delivered a hydrochloric acid gas removal tower to the steel industry. The absorption by water is Max 90°C. The treatment gas volume is 6750 Nm3/h, and the target gases and their concentrations are trace amounts of HCl, trace amounts of Cl2 gas, dust, and Fe2O3. The outlet concentration is below 5 ppm for hydrochloric acid gas, with chlorine gas and dust being at natural levels. [Case] ■ Industry of delivery: Steel manufacturing ■ Designed and installed equipment: Hydrochloric acid gas removal tower E730 series ■ Treatment gas volume: 6750 Nm3/h ■ Target gases and concentrations: trace amounts of HCl, trace amounts of Cl2 gas, dust, Fe2O3 ■ Outlet concentration ・Hydrochloric acid gas below 5 ppm ・Chlorine gas at natural levels ・Dust at natural levels *For more details, please refer to the PDF document or feel free to contact us.

  • Gas equipment
  • others

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Case Study of Environmental Equipment Installation] Salt Dust Removal Tower

Design removal rate of 90% or more for particles larger than 20μm! We will introduce examples of salt dust removal towers.

We would like to introduce a case where E-Techno supplied a salt dust removal tower to the food industry. The processing gas volume is 40m³/min. The target for removal is dust from the dryer, and the concentration is unknown. At a maximum processing gas temperature of 70°C, the designed removal rate is over φ20μm, exceeding 90%. 【Case Study】 ■ Industry of Delivery: Food ■ Designed and Installed Equipment: Salt Dust Removal Tower E730 Series ■ Processing Gas Volume: 40m³/min ■ Target Dust and Concentration: Dust from the dryer, concentration unknown ■ Processing Gas Temperature: Max. 70°C ■ Designed Removal Rate: Over φ20μm, over 90% *For more details, please refer to the PDF document or feel free to contact us.

  • Gas equipment
  • others

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Case Study of Environmental Equipment] Rubber Dust Removal Tower

Removal rate is over 90%! We will introduce a case study of an environmental device designed to remove rubber micro-dust.

We would like to introduce a case where I-Techno delivered a rubber dust removal tower. The processing gas volume is 100,800 Nm³/h, and the target for removal is fine rubber dust. The packing tower dimensions are ID 4515 × H7000. With washing using water, the removal rate exceeds 90%. 【Case Details】 ■ Industry of Delivery: Rubber Manufacturing ■ Designed and Installed Equipment: Rubber Dust Removal Tower ■ Processing Gas Volume: 100,800 Nm³/h ■ Target Dust for Removal: Fine Rubber Dust ■ Removal Rate: Over 90% ■ Packing Tower: ID 4515 × H7000 ■ Packing Material: Hi-Rex 300PP 33.6m³, 200PP 8.4m³ *For more details, please refer to the PDF document or feel free to contact us.

  • Gas equipment
  • others

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Case Study of Environmental Equipment] Moisture Removal Tower in Chlorine Gas - 3 Towers in Series

98% sulfuric acid concentration at the entrance and 60% at the exit! Concentrated sulfuric acid absorbs and removes moisture from chlorine gas!

We would like to introduce a case where I-Techno delivered three moisture removal towers in series for chlorine gas. Moisture is absorbed and removed from chlorine gas using concentrated sulfuric acid. The processing gas volume is 1300 Nm³/h of chlorine gas. With three towers in series, moisture is removed down to 30 wtppm from a saturation point of 20°C, and the sulfuric acid concentration is 98% at the inlet and 60% at the outlet. [Case Study] - Industry of Delivery: Chemical - Equipment Designed and Installed: Three moisture removal towers in series for chlorine gas - Processing Gas Volume: 1300 Nm³/h of chlorine gas - Moisture: Removed down to 30 wtppm from a saturation point of 20°C with three towers in series - Sulfuric Acid Concentration: 98% at the inlet, 60% at the outlet - Packing Material: Hyrex 1200 PVC 9.9 m³ × 3 *For more details, please refer to the PDF document or feel free to contact us.

  • Gas equipment
  • others

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration